Vertical Air Laminar Flow Cabinet TRVLC-605

Vertical Air Laminar Flow Cabinet TRVLC-605

Vertical Air Laminar Flow Cabinet TRVLC-605is equipped with a fan system with adjustable airflow at normal wind speeds of 0.25 to 0.45 m / s. It has a single, single dimension. There are HEPA filters and primary filters. With stainless steel, workspace, and glass sliding door. The maximum power consumption is 400W. A digital display panel with a liquid crystal-liquid interface controls the system. Comes with an outlet.

In Stock

Dimension Of Working Area(W1×D1×H1) 880×650×580mm
Half Ventilation Peak Value ≤ 3μm(XYZ direction)
Illumination ≥300LX
Maximum Power Consumption 400W
Noise ≤62dB
Number of Bacteria ≤0.5per utensil. Hour (90mm utensil)
Overall Dimension (W×D×H) 1040×720×1600mm
Power Supply AC, 220 V/50Hz
Specification And Number Of Fluorescent lamps Or UV Lamps Of Ultraviolet Lights 8W×1/10 W×1
Suited Number single-single
The Average Wind Speed 0.25 to 0.45m/s
The vertical closed worktop effectively prevents outside gas from entering and the weird odor
It employs a wind volume adjustable fan system
A light-touch type switch and a dual-speed voltage regulation device to maintain a suitable wind speed in the working area
The personalized design takes into account all of the user's requirements
It uses a spring-type sliding door that can be oriented in the desired position
It is designed to be operated easily
The front cover can be easily accessible to swap screens and electrical equipment
The work area is made with stainless steel, resistant to corrosion, and easy to clean
Having a digital display operates with a liquid crystal interface
It is having with the HEPA filter and primary filter
The HEPA filter ensures a clean environment in the work area
Biological Safety Cabinet TRBC-601

Biological Safety Cabinet TRBC-601

  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
  • Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
Biological Safety Cabinet TRBC-602

Biological Safety Cabinet TRBC-602

  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
  • Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
Biological Safety Cabinet TRBC-603

Biological Safety Cabinet TRBC-603

  • Number Of Colonies : ≤0.5pcs/dish hour (Φ90mm culture plate)
  • Average Wind Speed : 0.38 ± 0.025 m/s, 0.26 ± 0.025m/s, 0.27 ± 0.025m/s
  • Front Suction Wind Speed : 0.55m ± 0.025m/s (30% Efflux)
Biological safety cabinet TRBC-604
Biological safety cabinet TRBC-604
  • The Average Wind Speed- Inner Side : 0.38 + -0.025m/s
  • The Average Wind Speed- Middle : 0.26 + -0.025 m/S
  • The Average Wind Speed-Inside : 0.35 + -0.025 m/s