Energy Dispersion X-ray Fluorescence Spectrometer TRXS-601

Energy Dispersion X-ray Fluorescence Spectrometer TRXS-601

Energy Dispersion X-ray Fluorescence Spectrometer TRXS-601after being completely filtered by the optical filter, the original X-ray produced by the X-ray tube and exposed at a high voltage on the sample. It can do qualitative, quantitative, and no sample analysis. Almost all of the elements can be accurately analyzed. The types of elements contained in the sample have been qualitatively analyzed by the position and shape of the spectral peak. Filters are automatically selected and converted. It does not require operators to set multiple test parameters, with a historical query function and test data is automatically saved.

In Stock

Adc 2048 channels
Analysis Principle Energy-dispersive X-ray fluorescence analysis
Analysis Time 30 to 900seconds, adjustable
Channels 2048 
Constant Cooling Control 400 VDC
Current Variation 0 to rated power
Detector Si-PIN or SDD detector, high-speed pulse height analysis system
Element Measuring Range Any element from Na(11)-U(92)
Filter 6 filters
High Voltage Generator Special HV generator for X fluorescence
Input 85 to 265VAC,47 to 63 Hz
Minimum Measuring Limit Cd/Hg/Br/Cr/Pb≤2 ppm
Sample Exposure Diameter 2, 5, 8 mm
Sample Observation 200×color CCD camera
Sample Shape Arbitrary size, any irregular shape
Sample Type Plastic/metal/film/powder/liquid etc.
SDD Detector < 145 eV, > 1000/S, > 15 mm2, 0.025 mm, < 1.2 W
Stability 0.05%/8 h
System Power Control +5 VDC at 250 mA (1.2 W)
Temperature Variation voltage or current setting
Voltage Variation 0.0001
Working Environment Temperature 10 to 35 ˚C
Humidity 30 to 70% RH
X-Ray Tube Mo, 5 to 50 KV, 1 to 1000 A
One of the key indices used to measure the performance of an energy dispersive XRF spectrometer is the detector resolution
The X-ray tube can be shielded in full range, leaving only the side window for the X-ray outlet, which has specifically been treated with an embedded lead within
For high voltage, insulation and cooling, capillary oil can be utilized with a 0.005-inch Beryllium window, rated consumption power of 50W, and rated power of 50kV
Designed to last more than 5000 hours in service
Filters are selected and transformed automatically
The radiation-protected system, low-radiation ray tube, newly built and thoroughly treated
Design of a double-shielded lead plate that is completely enclosed
low-radiation x-ray tube that has been properly treated
The design features a double-shielded lead plate that is completely contained
Filtering device for lead plates that is self-contained. X-ray interrupters employed in the event of an unexpected cover opening
Testing for delays as well as an X-ray warning system
The workstation has analytical software installed. One-touch operation is easy and simple to use
Ergonomic human-machine interaction
It offers a sophisticated customizable report mechanism that eliminates the need for operators to set various test settings
Test data is automatically preserved when using a history query method
Methods of qualitative and quantitative analysis that are cutting-edge Hundreds of elements can be analyzed at once
Atomic Absorption Spectrophotometer TRAS-601

Atomic Absorption Spectrophotometer TRAS-601

  • Wavelength Range : 190 to 900 nm
  • Wavelength Accuracy : £ ±0.5 nm
  • Wavelength Repeatability : £ 0.3 nm (single direction)
Atomic Absorption Spectrophotometer TRAS-701

Atomic Absorption Spectrophotometer TRAS-701

  • Wavelength range  : 190 to 900 nm
  • Spectral bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Accuracy of the wavelength : ±0.15 nm