Single Beam UV VIS Spectrophotometer TRSUV-606

Single Beam UV VIS Spectrophotometer TRSUV-606

Single Beam UV VIS Spectrophotometer TRSUV-606 is a small device with a 7-inch multi-color touch screen. It has an automatic wavelength range of 190 to 1100 nm as well as a bandwidth of 2 nm. Having patented technology that allows for simple and effective human-computer interaction with a clear display of test data It has a photometric range of 0.0 to 200.0 % T, -0.301 to 4.000A, and 0.000 to 9999 C with an accuracy of 0.3 % T, 0.002Abs (0 to 0.5A) and 0.004Abs (0 to 9999 C) (0.5 to 1A). It includes a sample compartment for 5 to 50 mm cuvettes.

In Stock

Baseline Drift ± 0.002 Abs / 30 mins (250 nm and 500 nm after preheating warm-up for 2 hours )
Baseline Flatness -
Detector Silicon Photocell
Focal Length 160 mm
Grating 1200 lines/mm
Monochromatic Type Czerny-Turner
Noise 100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T)
Packing Size 630 mm×610 mm×500 mm
Photometric Accuracy ± 0.3% T, ± 0.002Abs (0 to 0.5 A) ± 0.004Abs (0.5 to 1 A)
Photometric Range 0.0 to 200.0% T,  -0.301 to 4.000A, 0.000 to 9999C
Photometric Repeatability ≤ 0.15% T, 0.001Abs (0 to 0.5 A) 0.002Abs (0.5 to 1 A)
Photometry Single Beam
Power AC220 V ± 22 V, 50Hz ± 1Hz, 180 W
Spectrum Bandwidth 2nm
Stray Light ≤ 0.1% ( at 220 nm NaI ; at 360 nm NaNO2)
Wavelength Accuracy ± 1 nm
Wavelength Range 190 to 1100 nm
Wavelength Repeatability ≤ 0.5 nm
Wavelength Scanning Speed -
Weight 0.16m³, 25 Kg
7-inch multi-color touch screen and patented technology for simple and effective human-computer interaction with clear test data display
A built-in thermal printer for printing test results and facilitating the creation and storage of data reports
A USB communication port and UV professional data processing software enables data processing and mapping functions
The storage of large amounts of data files, and help customers with a second development
Sample compartment for 5 to 50mm cuvettes
Automatic wavelength selection, which is both quick and accurate
Scanning kinetic time scanning, automatic wavelength, linear regression, direct concentration readout, peak detection, regular printing, and so on
Power shutdown protection measures that are advanced to memorize detector data and regression
To achieve fast initialization, the equation and instrument correction parameters must be known ahead of time
Lifelong safety for tungsten and deuterium lamps
Atomic Absorption Spectrophotometer TRAS-601

Atomic Absorption Spectrophotometer TRAS-601

  • Wavelength Range : 190 to 900 nm
  • Wavelength Accuracy : £ ±0.5 nm
  • Wavelength Repeatability : £ 0.3 nm (single direction)
Atomic Absorption Spectrophotometer TRAS-701

Atomic Absorption Spectrophotometer TRAS-701

  • Wavelength range  : 190 to 900 nm
  • Spectral bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Accuracy of the wavelength : ±0.15 nm